Dataset
Radon detectors: C-NRPP listed, not recommended and recalled
Consumer radon detectors with C-NRPP performance grade, listed or not recommended status and Health Canada recall status, each with source and date checked.
This table lists the consumer electronic radon monitors named in C-NRPP’s 2024/25 Consumer-grade Electronic Radon Monitor Performance Report, as we checked it on 18 October 2026. It keeps three statuses apart: C-NRPP’s consumer listing, C-NRPP’s professional approval and Health Canada’s recalls. Each status has its own source, and every row carries the date we checked it.
See each listed device’s own record
Listed and recommended means the monitor passed C-NRPP performance testing
A monitor that C-NRPP lists and recommends passed its performance testing with an average grade of A or B. The grade comes from the monitor’s measurement error over four test rounds. The table shows the grade from each round.
The rounds ran in the Radiation Safety Institute of Canada’s accredited chamber. Two ran at 200 Bq/m³, one in winter conditions and one in summer conditions. The other two ran at 400 and 1,000 Bq/m³.
Find out how to choose a test kit or monitor
Recalled monitors measured inaccurate radon levels
The recalled and flagged monitors in this table measured inaccurate radon levels. Some reported a low value no matter what the actual level was. For each of these devices, the table gives the Health Canada recall or advisory that C-NRPP links to, with that notice’s date.
Check one device’s statuses at a glance
Not recommended is not the same as recalled
Not recommended is C-NRPP’s status. A recall or advisory comes from Health Canada. A device can be not recommended without any recall. The table shows each status in its own column with its own source, so check both columns for any device you look up.
See what to do about a recalled monitor
Leave a listed monitor in place for a long-term test
C-NRPP says to leave a monitor in place for at least 3 months, preferably in the heating season. If you run it for less time, follow it with a long-term test. Base your decisions on the long-term average. No consumer monitor is approved for professional measurement.
Get the steps for a long-term test
How the table is built, and why it carries no licence yet
We transcribe each row from the C-NRPP report, its detailed results and the Health Canada notices as printed, with the date we checked. No row comes from a manufacturer or seller. The table covers consumer electronic monitors, and other device classes can be added at this same address.
Manufacturers choose whether to enter C-NRPP testing, so a device missing from the table may not have been tested. The data is derived from C-NRPP and Health Canada. It carries no licence statement until its terms are cleared.
Provenance
- Source
- C-NRPP 2024/25 Consumer-grade Electronic Radon Monitor Performance Report, its detailed results and testing-process documents, and the Health Canada notices C-NRPP links, each read on the date checked.
- Method
- Each row is transcribed from the C-NRPP report, its detailed-results document and the Health Canada notice pages as printed, with the date checked. Purchase-link eligibility is computed from these fields and never stored. No row is typed from a manufacturer or seller.
- Date checked
- 2026-10-18
- Next review
- 2026-11-18
Column schema
Fields in this dataset
| Column | Type | Description |
|---|---|---|
| id | string | The device's slug; its page URL's last segment when it has a page. |
| name | string | Brand and model as C-NRPP prints them. |
| brand | string | Manufacturer or brand as printed. |
| model | string | Model as printed. |
| category | string | monitor (consumer electronic radon monitor) or test-kit. |
| cnrpp_consumer_listing | string | recommended or not-recommended, in the report's own words. A consumer device is never called approved. |
| cnrpp_professional_approval | string | approved or not-approved for use by radon measurement professionals. Consumer monitors are not approved. |
| in_performance_table | boolean | True when the device was tested in the intercomparison and has grades. Only these devices have a page. |
| report_edition | string | The C-NRPP report edition the row comes from. |
| grade_round_1 | string | Performance grade in round 1 (218 Bq/m³, 23 °C, 28% RH, 7 days). A to E; empty when not tested. |
| grade_round_2 | string | Performance grade in round 2 (210 Bq/m³, 29 °C, 70% RH, 7 days). |
| grade_round_3 | string | Performance grade in round 3 (436 Bq/m³, 23 °C, 36% RH, 7 days). |
| grade_round_4 | string | Performance grade in round 4 (1201 Bq/m³, 23 °C, 35% RH, 7 days). |
| cnrpp_label | string | The label C-NRPP prints beside a not-recommended row, verbatim. |
| stated_accuracy | string | The manufacturer's stated accuracy as C-NRPP prints it. Not a measured result. |
| recall_status | string | none, recall or advisory, from the Health Canada notice C-NRPP links. |
| recall_notice_id | string | The notice's identification number on recalls-rappels.canada.ca. |
| recall_notice_updated | date | The notice page's last-updated date. |
| recall_notice_url | string | The notice page. |
| recall_notice_names_model | boolean | Whether the linked notice names this brand and model. False where C-NRPP links a notice that does not. |
| recall_note | string | What the linked notice says where it differs from C-NRPP's row. |
| page | string | The device's page on this site, when it has one. |
| date_checked | date | The date the sources were read. |
The data
Radon detectors: C-NRPP listed, not recommended and recalled
One record per consumer electronic radon monitor named in C-NRPP's 2024/25 Consumer-grade Electronic Radon Monitor Performance Report: the six it recommends, with their performance grade in each of four test rounds, and the fourteen it does not recommend, with the Health Canada recall or advisory C-NRPP links for each, the notice's number and date, and whether that notice names the model. Three statuses are kept separate: C-NRPP consumer listing, C-NRPP professional approval and Health Canada recall.
| id | name | brand | model | category | cnrpp_consumer_listing | cnrpp_professional_approval | in_performance_table | report_edition | grade_round_1 | grade_round_2 | grade_round_3 | grade_round_4 | cnrpp_label | stated_accuracy | recall_status | recall_notice_id | recall_notice_updated | recall_notice_url | recall_notice_names_model | recall_note | page | date_checked |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| air-steward-portable-radon-monitor | Air Steward Portable Radon Monitor | Air Steward | Portable Radon Monitor | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | Recalled by Health Canada | no data | recall | RA-64544 | 2022-09-13 | https://recalls-rappels.canada.ca/en/alert-recall/air-steward-portable-radon-monitor-recalled-due-inaccurate-radon-detection | true | no data | no data | 2026-10-18 |
| airthings-corentium-home | Airthings Corentium Home | Airthings | Corentium Home | monitor | recommended | not-approved | true | 2024/25 | A | A | A | A | no data | ±10% (after 7 days at 200 Bq/m³), ±5% after 2 months of monitoring | none | no data | no data | no data | no data | no data | /devices/airthings-corentium-home/ | 2026-10-18 |
| airthings-view | Airthings View | Airthings | View | monitor | recommended | not-approved | true | 2024/25 | B | C | B | B | no data | After 30 days at 200 Bq/m³, ±10% on the 7 day average and ±5% on the 2 month average | none | no data | no data | no data | no data | no data | /devices/airthings-view/ | 2026-10-18 |
| aranet-rn-plus | Aranet RN+ | Aranet | RN+ | monitor | recommended | not-approved | true | 2024/25 | A | A | A | A | no data | ±8% accuracy of 24 h, 7 d, 30 d averages | none | no data | no data | no data | no data | no data | /devices/aranet-rn-plus/ | 2026-10-18 |
| bootu-rn-80 | Bootu RN-80 | Bootu | RN-80 | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | NOT APPROVED | no data | none | no data | no data | no data | no data | no data | no data | 2026-10-18 |
| boyd-gresham-radon-detector | Boyd Gresham Radon Detector | Boyd Gresham | Radon Detector | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | Radon Detector – Recalled by HEALTH CANADA | no data | advisory | RA-77383 | 2025-05-07 | https://recalls-rappels.canada.ca/en/alert-recall/health-canada-warns-various-radon-gas-detectors-sold-amazonca-may-pose-health-and | true | The advisory names the Boyd Gresham "Toolhome" Radon Detector, model HRDM-01B. | no data | 2026-10-18 |
| cradtec-prm-02h | CRADTEC PRM-02H | CRADTEC | PRM-02H | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | NOT APPROVED | no data | none | no data | no data | no data | no data | no data | no data | 2026-10-18 |
| cradtec-prm-03h | CRADTEC PRM-03H | CRADTEC | PRM-03H | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | NOT APPROVED | no data | none | no data | no data | no data | no data | no data | no data | 2026-10-18 |
| ecosense-ecoqube | Ecosense EcoQube | Ecosense | EcoQube | monitor | recommended | not-approved | true | 2024/25 | A | A | A | A | no data | ±10% at 370 Bq/m³ after 10 hours of measurement | none | no data | no data | no data | no data | no data | /devices/ecosense-ecoqube/ | 2026-10-18 |
| ecosense-radoneye | Ecosense RadonEye | Ecosense | RadonEye | monitor | recommended | not-approved | true | 2024/25 | A | A | A | A | no data | ±10% at 370 Bq/m³ after 10 hours of measurement | none | no data | no data | no data | no data | no data | /devices/ecosense-radoneye/ | 2026-10-18 |
| funny-kitchen-hrdm-02 | Funny Kitchen HRDM-02 | Funny Kitchen | HRDM-02 | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | HRDM-02 - Recalled by HEALTH CANADA | no data | advisory | RA-77383 | 2025-05-07 | https://recalls-rappels.canada.ca/en/alert-recall/health-canada-warns-various-radon-gas-detectors-sold-amazonca-may-pose-health-and | true | no data | no data | 2026-10-18 |
| hakinaku-smart-radon-gas-detector | HAKINAKU Smart Radon Gas Detector | HAKINAKU | Smart Radon Gas Detector | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | NOT APPROVED | no data | none | no data | no data | no data | no data | no data | no data | 2026-10-18 |
| hanchen-home-radon-detector | Hanchen Home Radon Detector | Hanchen | Home Radon Detector | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | Home Radon Detector- Recalled by Health Canada | no data | recall | RA-77403 | 2025-05-15 | https://recalls-rappels.canada.ca/en/alert-recall/hanchen-home-radon-detector-recalled-due-inaccurate-radon-detection | true | no data | no data | 2026-10-18 |
| inkbird-home-radon-meter | INKBIRD Home Radon Meter | INKBIRD | Home Radon Meter | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | Home Radon Meter – Recalled by Health Canada | no data | recall | RA-77444 | 2025-05-30 | https://recalls-rappels.canada.ca/en/alert-recall/various-life-basis-brand-radon-detectors-recalled-due-inaccurate-radon-detection | false | C-NRPP's table links the Life Basis notice for this row; that notice names Life Basis models LSRM001 and LCARM001 and no INKBIRD model. Raised with C-NRPP. | no data | 2026-10-18 |
| inkbird-ink-rd2 | INKBIRD INK-RD2 | INKBIRD | INK-RD2 | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | INK-RD2 –Recalled by Health Canada | no data | recall | RA-77461 | 2025-05-30 | https://recalls-rappels.canada.ca/en/alert-recall/inkbird-wifi-radon-detector-model-rd-2-recalled-due-inaccurate-radon-detection | true | no data | no data | 2026-10-18 |
| lifebasis-lcarm001 | LifeBasis LCARM001 | LifeBasis | LCARM001 | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | LCARM001 – Recalled by Health Canada | no data | recall | RA-77444 | 2025-05-30 | https://recalls-rappels.canada.ca/en/alert-recall/various-life-basis-brand-radon-detectors-recalled-due-inaccurate-radon-detection | true | no data | no data | 2026-10-18 |
| lifebasis-rn-55 | LifeBasis RN-55 | LifeBasis | RN-55 | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | RN-55 – Recalled by Health Canada | no data | recall | RA-77444 | 2025-05-30 | https://recalls-rappels.canada.ca/en/alert-recall/various-life-basis-brand-radon-detectors-recalled-due-inaccurate-radon-detection | false | The notice names Life Basis models LSRM001 and LCARM001; it does not print "RN-55". Raised with C-NRPP. | no data | 2026-10-18 |
| radon-guard | Radon Guard | Radon Guard | Radon Guard | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | Recalled by Health Canada | no data | recall | no data | no data | no data | false | C-NRPP's table links a Health Canada notice address that did not resolve when checked. The live advisory for the Elifecity Portable Radon Meter (RA-64529, last updated 2022-09-07) does not name Radon Guard. The recall status here rests on C-NRPP's table alone. Raised with C-NRPP. | no data | 2026-10-18 |
| spolehli-radon-detector | Spolehli Radon Detector | Spolehli | Radon Detector | monitor | not-recommended | not-approved | false | 2024/25 | no data | no data | no data | no data | Radon Detector – Recalled by Health Canada | no data | recall | RA-77362 | 2025-05-01 | https://recalls-rappels.canada.ca/en/alert-recall/spolehli-radon-detector-recalled-due-inaccurate-radon-detection | true | no data | no data | 2026-10-18 |
| sunradon-luft | SunRadon Luft | SunRadon | Luft | monitor | recommended | not-approved | true | 2024/25 | A | A | A | A | no data | ±10% (after 7 days at 200 Bq/m³) | none | no data | no data | no data | no data | no data | /devices/sunradon-luft/ | 2026-10-18 |
20 rows
Canadian National Radon Proficiency Program (C-NRPP), 2024/25 Consumer-grade Electronic Radon Monitor Performance Report.
Cite this
Canadian Radon Services Index (2026). Radon detectors: C-NRPP listed, not recommended and recalled [Data set]. SIUYA INC. https://canadianradonservicesindex.ca/data/radon-devices/
Select the text to copy it if scripts are off.