Menu

Radon device

Airthings Corentium Home 2

How the Airthings Corentium Home 2 radon detector did in Health Canada's lab testing, its recall status and what its maker states, each with source and date.

Consumer electronic radon monitor

Airthings Corentium Home 2

A consumer electronic radon monitor made by Airthings. Health Canada's lab tested it in a published study. This page is the record: the lab result, the recall status and what the maker says, each with its source and date. Health Canada's advice is to choose an electronic monitor "that has passed the C-NRPP performance testing." Its brochure is linked in the sources below.

What Health Canada's lab found

Lab study results for Airthings Corentium Home 2

The middle column says whether the model's average error against a reference stayed under the study's limit. The last column is from the study's longest test. A field test in one home is shown for comparison and doesn't count toward the device rules. Findings are in our words, not copied from the study.

StudyAgainst the study's error limitLong-term test
Government lab study, published 2026-10-19Within the 25% limitAfter 13 weeks in the chamber, it was off by 2% on average. It was 26% off after one day and settled within the first few weeks.

Lemieux A, Brewer S, Mekarski P. Advancing understanding of temporal performance and behaviour in consumer-grade electronic radon monitors. Radiation Protection Dosimetry, published online 2026-10-19. DOI 10.1093/rpd/ncag121.

Recall status and what the maker says

Recall status, maker's statements and device rules for Airthings Corentium Home 2, checked 2026-11-10

Lines marked as the maker's are the maker's own words, not measured results. The device rules decide whether a purchase link shows.

ItemValue
Health Canada recall statusNo recall or advisory names it
Accuracy, as the maker states itAccuracy/Precision within 10%: 4 days at 10 pCi/L (370 Bq/m³) 7 days at 5.4 pCi/L (200 Bq/m³)
Long-term average, as the maker states itSays it gives an average over 3 months or longer: "The cumulative view provides an all-time average and tells you how long it’s been since you began the measurement. When it reaches 365 days, it turns into your rolling 1 year average."
Sold in CanadaYes: Airthings Canada store, Corentium Home 2 product page
Purchase link under our device rulesShown: it meets all four device rules

Health Canada, Recalls and Safety Alerts open data (HCRSAMOpenData), Open Government Licence - Canada. The maker's statements are from https://www.airthings.com/manuals/corentium-home-2.

Manufacturer links are labelled. They pay us nothing, and no device pays to be listed or for its place in the order. Read our device rules

What to do next

Provenance

Source
Health Canada's 2025 lab study of electronic radon monitors, Health Canada's recall and advisory notices, and the maker's own pages, each read on the date checked.
Method
We state the study's findings in our own words and link the study. Recall status comes from Health Canada's notices. The maker's lines are quoted as the maker's. The card state and any purchase link are worked out from the record at every build. Nothing is typed by hand.
Date checked
2026-11-10
Next review
2027-02-10
Report an error in this record