How Airthings Corentium Home performed in C-NRPP accuracy testing, whether it is listed, its Health Canada recall status and specifications, each with source and date.

The Airthings Corentium Home radon monitor, a small handheld unit with a digital display.

Consumer electronic radon monitor

Airthings Corentium Home

A consumer-grade electronic radon monitor made by Airthings, tested by C-NRPP in its 2024/25 intercomparison. This page is the record: result, listing status, recall status and the figures C-NRPP prints, each with its source and date.

How it performed in C-NRPP testing

C-NRPP 2024/25 performance grades for Airthings Corentium Home, by test round

Grade A is a measurement error of 10% or less; B over 10 to 20; C over 20 to 30; D over 30 to 40; E over 40. Measurement error combines accuracy and precision. Three units of each model were tested unopened.

Test roundRadon level (Bq/m³)Temperature (°C)Humidity (% RH)Duration (days)Grade
Round 121823287A
Round 221029707A
Round 343623367A
Round 41,20123357A

C-NRPP, Consumer-Grade Electronic Radon Monitors: Summary of Method and Detailed Results, 2024/2025 project, published May 2025.

Status and stated specifications

Status of Airthings Corentium Home and the figures C-NRPP prints, 2024/25 report

The accuracy, reading frequency, display and power lines are the manufacturer's stated figures as C-NRPP prints them, not measured results.

ItemValue
C-NRPP consumer listingRecommended
C-NRPP professional approvalNot approved for professional use
Health Canada recall statusNo recall or advisory listed
Manufacturer-stated accuracy±10% (after 7 days at 200 Bq/m³), ±5% after 2 months of monitoring
Frequency of reading12 hours, 24 hours, 7 days (first reading will take 24 hrs)
Display or appShort-term and long-term average shown on monitor display.
Battery or plug-inBattery

Canadian National Radon Proficiency Program (C-NRPP), 2024/25 Consumer-grade Electronic Radon Monitor Performance Report.

Purchase and manufacturer links are labelled. We may earn a commission on a purchase link; a manufacturer link pays us nothing. Neither changes which devices are listed, their order or what is said about them. Read the affiliate disclosure and device rules

Provenance

Source
C-NRPP 2024/25 Consumer-grade Electronic Radon Monitor Performance Report, its detailed results and testing-process documents, and the Health Canada notice where C-NRPP links one.
Method
Status and grades are transcribed from the C-NRPP documents as printed. The card state and any purchase link are computed from the record: a device with a recall or advisory, or off the recommended list, gets no purchase element. Nothing is typed by hand.
Date checked
2026-10-18
Next review
2027-01-18