How it performed in C-NRPP testing

C-NRPP 2024/25 performance grades for Ecosense EcoQube, by test round

Grade A is a measurement error of 10% or less; B over 10 to 20; C over 20 to 30; D over 30 to 40; E over 40. Measurement error combines accuracy and precision. Three units of each model were tested unopened.

Test roundRadon level (Bq/m³)Temperature (°C)Humidity (% RH)Duration (days)Grade
Round 121823287A
Round 221029707A
Round 343623367A
Round 41,20123357A

C-NRPP, Consumer-Grade Electronic Radon Monitors: Summary of Method and Detailed Results, 2024/2025 project, published May 2025.

Status and stated specifications

Status of Ecosense EcoQube and the figures C-NRPP prints, 2024/25 report

The accuracy, reading frequency, display and power lines are the manufacturer's stated figures as C-NRPP prints them, not measured results.

ItemValue
C-NRPP consumer listingRecommended
C-NRPP professional approvalNot approved for professional use
Health Canada recall statusNo recall or advisory listed
Manufacturer-stated accuracy±10% at 370 Bq/m³ after 10 hours of measurement
Frequency of readingMeasures every 10 minutes and displays an hourly rolling average.
Display or appHourly levels are displayed on LED; short-term and long-term averages, and hourly data points on the mobile app.
Battery or plug-inPlug in

Canadian National Radon Proficiency Program (C-NRPP), 2024/25 Consumer-grade Electronic Radon Monitor Performance Report.

Purchase and manufacturer links are labelled. We may earn a commission on a purchase link; a manufacturer link pays us nothing. Neither changes which devices are listed, their order or what is said about them. Read the affiliate disclosure and device rules

Provenance

Source
C-NRPP 2024/25 Consumer-grade Electronic Radon Monitor Performance Report, its detailed results and testing-process documents, and the Health Canada notice where C-NRPP links one.
Method
Status and grades are transcribed from the C-NRPP documents as printed. The card state and any purchase link are computed from the record: a device with a recall or advisory, or off the recommended list, gets no purchase element. Nothing is typed by hand.
Date checked
2026-10-18
Next review
2027-01-18
Report an error in this record